Public trial
RBR-23kwzb Effects of Therapeutic Currents in Health Subjects
Date of registration: 10/30/2013 (mm/dd/yyyy)Last approval date : 10/30/2013 (mm/dd/yyyy)
Study type:
Interventional
Scientific title:
en
Comparison of Sensorial Discomfort and Peak Torque During Neuromuscular Electric Stimulation With Medium and Low Frequency Currents
pt-br
Comparação do Índice de Desconforto Sensorial e Pico de Torque Durante a Estimulação Elétrica Neuromuscular com Correntes de Média e Baixa Frequência
Trial identification
- UTN code: U1111-1136-0674
-
Public title:
en
Effects of Therapeutic Currents in Health Subjects
pt-br
Efeitos de Correntes Terapêuticas em Indivíduos Saudáveis
-
Scientific acronym:
-
Public acronym:
-
Secondaries identifiers:
-
Nº 021/2011
Issuing authority: CEP/Comitê de Ética em Pesquisa do UNICEP
-
Nº 021/2011
Sponsors
- Primary sponsor: Univerdade Federal de São Carlos
-
Secondary sponsor:
- Institution: Universidade de Brasília
-
Supporting source:
- Institution: Univerdade Federal de São Carlos
Health conditions
-
Health conditions:
en
Healthy subjects, muscular performance, sensory discomfort elicited by electrical stimulation.
pt-br
Indivíduos saudáveis, desempenho muscular, desconforto sensorial eliciado pela estimulação elétrica
-
General descriptors for health conditions:
en
I03.450.642.845.054 Sport performance, rehabilitation
pt-br
I03.450.642.845.054 Desempenho esportivo, reabilitação
-
Specific descriptors:
Interventions
-
Interventions:
en
Subjects were randomized to receive four common forms: two medium frequency and two low frequency (Australian current "with 1000Hz frequency modulated bursts of 50Hz, 4ms of burst duration and interburst interval of 16 ms), with duration of up 500?s; Russian current with 2500Hz frequency modulated bursts of 50Hz, 10ms burst duration and interburst interval with 200?s duration of phase, low frequency, 50 Hz with phase duration 500?s and 50 Hz with phase duration of 200?s. .) All treatments were applied to the same experimental units after grouping them into groups of equal number to the number of treatments. All the volunteers have receive the same interventions.
pt-br
Indivíduos foram randomizados para receber quatro formas correntes: duas de media frequência e duas de baixa frequência (corrente Australiana", com 1000Hz frequência modulada em bursts de 50Hz, 4ms de duração de burst e intervalo interburst de 16 ms), com duração da fase de 500?s; corrente Russa, com 2500Hz frequência modulada em bursts de 50Hz, 10ms de duração de burst e intervalo interburst com 200?s de duração de fase; baixa frequência, 50 Hz com duração de fase de 500?s e 50 Hz com duração da fase de 200?s.). Todos os tratamentos foram aplicados às mesmas unidades experimentais, após agrupá-las em grupos de número igual ao número de tratamentos. As voluntárias receberam todas as intervenções.
-
Descriptors:
en
E02.779 Physical Therapy Modalities
pt-br
E02.779 Modalidades de Fisioterapia
es
E02.779 Modalidades de Fisioterapia
Recruitment
- Study status: Data analysis completed
-
Countries
- Brazil
- Date first enrollment: 01/18/2012 (mm/dd/yyyy)
-
Target sample size: Gender: Minimum age: Maximum age: 21 F 18 Y 30 Y -
Inclusion criteria:
en
Being female, healthy, physically active, aged between 18 and 30 years, body mass index (BMI) between 20 and 25 kg / m², with range of motion and knee function preserved, free from orthopedic diseases, pulmonary, cardiovascular, immune, and metabolic or chronic.
pt-br
Ser do gênero feminino, saudável, fisicamente ativo, idade entre 18 e 30 anos, índice de massa corporal (IMC) entre 20 e 25 kg / m², com amplitude de movimento e função do joelho preservada, livres de doenças ortopédicas, pulmonar, cardiovascular, imunológica, e ou metabólica crônica.
-
Exclusion criteria:
en
Age above 30 years. Male.
pt-br
Idade acima de 30 anos. Gênero masculino.
Study type
-
Study design:
-
Expanded access program Purpose Intervention assignment Number of arms Masking type Allocation Study phase Prevention Cross-over 4 Triple-blind Randomized-controlled N/A
Outcomes
-
Primary outcomes:
en
Medium frequency currents would be more comfortable in up to 15% compared to low frequency assessed by visual analog scale. Medium frequency currents would bring no advantage in muscle strength compared to low frequency current assessed by isokinetic dynamometry. The association of voluntary muscle contraction with the contraction elicited by electrical current would not result in additional gains in muscle strength assessed by isokinetic dynamometry and visual analog scale.
pt-br
Correntes de média frequência seriam mais confortáveis em até 15% em relação a baixa frequência avaliada pela escala analógica visual. Correntes de média frequência não trariam vantagem na força muscular comparada a corrente de baixa frequência avaliada por dinamometria isocinética. A associação da contração muscular voluntária com a contração eliciada pela corrente elétrica não resultaria em ganhos adicionais na força muscular avaliada por dinamometria isocinética e escala analógica visual.
en
The currents of medium and low frequency did not differ with respect to discomfort by visual analog scale. The current Russian medium frequency produced lower values ??of strength (20%) compared with the other evaluated by isokinetic dynamometry. There was no difference between the association of voluntary muscle contraction with the contraction elicited by electrical current in muscle strength assessed by isokinetic dynamometry and visual analog scale.
pt-br
As correntes de media e baixa frequência não foram diferentes com relação ao desconforto pela escala analógica visual. A corrente russa de média frequência produziu os menores valores de força (20%) comparado as demais avaliada por dinamometria isocinética. Não houve diferença entre a associação da contração muscular voluntária com a contração eliciada pela corrente elétrica na força muscular avaliada por dinamometria isocinética e escala analógica visual.
-
Secondary outcomes:
en
The contraction elicited by electrical current would be 40% less effective than voluntary contraction assessed by isokinetic dynamometry.
pt-br
A contração eliciada pela corrente elétrica seria 40% menos efetiva do que a contração voluntaria avaliada por dinamometria isocinética.
en
There is no advantage in associating with the electric current voluntary contraction or electrical current to only gain strength as the current generated 37.7% less muscle strength when compared to isolated voluntary contraction. This variable was measured by isokinetic dynamometry.
pt-br
Não há vantagem em associar a corrente elétrica com a contração voluntaria, ou somente a corrente elétrica para ganho de força, pois a corrente gerou 37,7% menos força muscular quando comparada a contração voluntaria isolada. Essa variável foi medida por dinamometria isocinética.
Contacts
-
Public contact
- Full name: João Luiz Quagliotti Durigan
-
- Address: QNN 14 Área Especial – Ceilândia Sul
- City: Brasília / Brazil
- Zip code: 72220-140
- Phone: +55(61)3107-8401
- Email: joaodurigan@gmail.com
- Affiliation: Universidade de Brasília
-
Scientific contact
- Full name: João Luiz Quagliotti Durigan
-
- Address: QNN 14 Área Especial – Ceilândia Sul
- City: Brasília / Brazil
- Zip code: 72220-140
- Phone: +55(61)3107-8401
- Email: joaodurigan@gmail.com
- Affiliation: Universidade de Brasília
-
Site contact
- Full name: João Luiz Quagliotti Durigan
-
- Address: QNN 14 Área Especial – Ceilândia Sul
- City: Brasília / Brazil
- Zip code: 72220-140
- Phone: +55(61)3107-8401
- Email: joaodurigan@gmail.com
- Affiliation: Universidade de Brasília
Additional links:
Total de Ensaios Clínicos 17440.
Existem 8769 ensaios clínicos registrados.
Existem 4835 ensaios clínicos recrutando.
Existem 90 ensaios clínicos em análise.
Existem 5883 ensaios clínicos em rascunho.