Public trial
RBR-7m82zcf DAMA: Device for assessing the walking of people Post-Stroke
Date of registration: 02/17/2025 (mm/dd/yyyy)Last approval date : 02/17/2025 (mm/dd/yyyy)
Study type:
Observational
Scientific title:
en
DAMA: Portable device for kinematic Assessment of Gait in Post-Stroke individuals
pt-br
DAMA: Dispositivo portátil para Avaliação cinemática da Marcha de indivíduos pós Acidente Vascular Cerebral
es
DAMA: Portable device for kinematic Assessment of Gait in Post-Stroke individuals
Trial identification
- UTN code: U1111-1313-8370
-
Public title:
en
DAMA: Device for assessing the walking of people Post-Stroke
pt-br
DAMA: Dispositivo para avaliar a caminhada de pessoas pós Acidente Vascular Cerebral - AVC
-
Scientific acronym:
en
DAMA
pt-br
DAMA
-
Public acronym:
en
DAMA
pt-br
DAMA
-
Secondaries identifiers:
-
64206422.8.0000.5537
Issuing authority: Plataforma Brasil
-
6.046.205
Issuing authority: Comitê de Ética em Pesquisa da Universidade Federal do Rio Grande do Norte
-
64206422.8.0000.5537
Sponsors
- Primary sponsor: Universidade Federal do Rio Grande do Norte
-
Secondary sponsor:
- Institution: Instituto Federal de Educação, Ciência e Tecnologia do Rio Grande do Norte
-
Supporting source:
- Institution: Conselho Nacional de Desenvolvimento Científico e Tecnológico
- Institution: Fundação Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
Health conditions
-
Health conditions:
en
Stroke
pt-br
Acidente Vascular Cerebral
-
General descriptors for health conditions:
en
C10.228 Central Nervous System Diseases
pt-br
C10.228 Doenças do Sistema Nervoso Central
-
Specific descriptors:
en
C10.228.140.300.775 Stroke
pt-br
C10.228.140.300.775 Acidente Vascular Cerebral
Interventions
-
Interventions:
en
This study is characterized as a validation and reliability test, following the recommendations of the Evaluating Connected Sensors Technologies - EVIDENCE checklist. The 15 post-stroke and 15 non-stroke participants will be assessed and their clinical and anthropometric data obtained. They will then be given the 10-meter walk test, the Functional Ambulatory Category (FAC) and the Fugl-Meyer Assessment - Lower Extremity (FMA-LE) scales (these last two instruments will only be used for the post-stroke participants). Next, data will be collected with the two gait analysis systems simultaneously: the Qualisys® system and the DAMA (Device for assessing the walking of people Post-Stroke) device. To do this, participants will be instructed to walk using their usual footwear on a straight, flat stretch of approximately 4 meters, maintaining their usual, comfortable speed (self-selected). This procedure will be repeated 10 times in order to obtain the average of the data collected. After collection with the devices, questionnaires relating to the operational usability of the device (answered by the evaluators) and the user satisfaction questionnaire (answered by the participants) will be applied
pt-br
Este estudo se caracteriza como validação e um teste de confiabilidade, seguindo as recomendações do Evaluating Connected Sensors Technologies – EVIDENCE checklist. Os 15 Participantes pós-AVC (Acidente Vascular Cerebral) e 15 participantes sem AVC(Acidente Vascular Cerebral) serão avaliados e obtidos os seus dados clínicos e antropométricos. Em seguida serão aplicados o Teste de Caminhada 10 metros, as escalas Functional Ambulatory Category (FAC) e Fugl-Meyer Assessment - Lower Extremity (FMA-LE) (esses dois últimos instrumentos será apenas para os participantes pós-AVC (Acidente Vascular Cerebral)). Em seguida, ocorrerá a coleta de dados com os dois sistemas de análise de marcha simultaneamente: o sistema Qualisys® e o dispositivo DAMA (Dispositivo para avaliar a caminhada de pessoas pós Acidente Vascular Cerebral). Para isto, os participantes serão instruídos a caminhar usando seu calçado usual em um trecho retilíneo e plano de aproximadamente 4 metros, mantendo sua velocidade habitual e confortável (auto selecionada). Este procedimento será repetido 10 vezes, a fim de obter a média dos dados coletados. Após a coleta com os dispositivos, serão aplicados os questionários relacionados a usabilidade operacional do dispositivo (respondido pelos avaliadores) e o questionário de satisfação dos usuários (respondido pelos participantes)
-
Descriptors:
en
E07.796 Assistive Technology
pt-br
E07.796 Tecnologia Assistiva
Recruitment
- Study status: Recruiting
-
Countries
- Brazil
- Date first enrollment: 10/01/2024 (mm/dd/yyyy)
-
Target sample size: Gender: Minimum age: Maximum age: 30 - 20 Y 70 Y -
Inclusion criteria:
en
For individuals without a stroke - individuals who do not have any neurological, orthopedic or rheumatological condition that affects walking; of both genders; aged between 20 and 70 years. For individuals with stroke - have a diagnosis of stroke; of any etiology; at any stage of this condition (acute, subacute or chronic); be able to walk independently indoors - Functional Ambulation Category - FAC scores equal to or greater than 3; who do not use a walking aid; who do not have unstable heart conditions - New York Heart Association (NYHA) scores equal to or greater than 3; who do not have a clinical condition other than stroke that affects walking; of either gender; aged between 20 and 70 years old
pt-br
Para indivíduos sem Acidente Vascular Cerebral AVC - indivíduos que não tenham nenhuma condição neurológica, ortopédica, ou reumatológica que afete a marcha; de ambos os gêneros; com idades entre 20 e 70 anos. Para indivíduos com Acidente Vascular Cerebral AVC - possuir diagnóstico de AVC; de qualquer etiologia; em qualquer estágio dessa condição (agudo, subagudo ou crônico); ser capaz de caminhar de maneira independente em ambientes fechados - escores da Categoria de Deambulação Funcional – FAC iguais ou superiores a 3; que não façam uso de dispositivo auxiliar de marcha; não apresentar condições cardíacas instáveis- escores da New York Heart Association -NYHA iguais ou superiores a 3; não possuir outra condição clínica além do AVC que afete a marcha; de ambos os gêneros; com idades entre 20 e 70 anos
-
Exclusion criteria:
en
Participants who for any reason feel unable to complete the evaluation protocol
pt-br
Participantes que por qualquer motivo se sintam impossibilitados de completar o protocolo de avaliação
Study type
-
Study design:
-
Expanded access program Purpose Intervention assignment Number of arms Masking type Allocation Study phase
Outcomes
-
Primary outcomes:
en
Investigate the validity and reliability of the device by comparing the kinematic parameters with the gold standard method (Qualisys) using the Wilcoxon test
pt-br
Investigar a validade e confiabilidade do dispositivo realizando a comparação dos parâmetros cinemáticos com o método padrão-ouro (Qualisys) por meio do teste de Wilcoxon
-
Secondary outcomes:
en
We expect to observe the ankle kinematic data (maximum dorsiflexion and plantar flexion angle, ankle angle at initial contact and toe-off) provided by the Qualisys system and the DAMA device
pt-br
Espera-se observar os dados cinemáticos do tornozelo (ângulo máximo de dorsiflexão e de flexão plantar, o ângulo do tornozelo no contato inicial e no toe-off) fornecidos pelo sistema Qualisys e pelo dispositivo DAMA
Contacts
-
Public contact
- Full name: Lígia Pablícia Lopes Dantas
-
- Address: Av. Sen. Salgado Filho, 3000
- City: Natal / Brazil
- Zip code: 59078-970
- Phone: +55(84)99229-6613
- Email: ligia.dantas.109@ufrn.edu.br
- Affiliation: Universidade Federal do Rio Grande do Norte
-
Scientific contact
- Full name: Tatiana Souza Ribeiro
-
- Address: Av. Senador Salgado Filho
- City: Natal / Brazil
- Zip code: 59078-970
- Phone: +55(84) 99229-6613
- Email: tatiana.ribeiro@ufrn.br
- Affiliation: Universidade Federal do Rio Grande do Norte
-
Site contact
- Full name: Tatiana Souza Ribeiro
-
- Address: Av. Senador Salgado Filho
- City: Natal / Brazil
- Zip code: 59078-970
- Phone: +55(84) 99229-6613
- Email: tatiana.ribeiro@ufrn.br
- Affiliation: Universidade Federal do Rio Grande do Norte
Additional links:
Total de Ensaios Clínicos 16842.
Existem 8285 ensaios clínicos registrados.
Existem 4660 ensaios clínicos recrutando.
Existem 310 ensaios clínicos em análise.